With C14/C13 in a shunt, one common flue under positive pressure goes into the main duct, with a tee per boiler. You choose between rigid stainless steel, PZ C14 Star in black PP or PR C14 Flexible.

Read more

Enter the number of appliances and the height above to see which parts you need.

How C14 and C13 work in a shunt

All boilers discharge into one column in the main duct of the shunt. Each boiler has a tee in that column. With C14 the air enters at the top of the shaft and flows down around the column, in counterflow with the flue gas. With C13 there is also one common flue, but each appliance takes its air separately. Both are approved as one unit with the boiler.

Only use boilers approved for a collective flue under positive pressure, C(10) or C(14), according to gas.be (NBN D 51-003 annex E). Each boiler has backflow protection, built into the boiler or with a flap. The concentric connection has a fall of at least 3° towards the boiler.

In the shunt the partition may be drilled through, so the branch ducts also supply air. Old connections and hatches are closed, no other pipes run in the shaft and ventilation of the dwellings is arranged separately.

Three versions

Rigid stainless steelPZ C14 StarPR C14 Flexible
MaterialStainless steel 316, IE rangeRigid black PPFlexible PP
TeeWith ø80 branchWith screw-off connection pipe ø60 or ø80Connection set per boiler
At the bottom of the shuntStarter support plateSupport foot and condensate drainBase set and condensate element
ExpansionNo separate partAbsorber under each teeTaken up by the flexible liner
Choose this ifThe main duct is straight and you want stainless steelThe main duct is straight and you want one ø130 mm core hole per boilerThe shunt has offsets or is not straight

With PZ C14 Star the column is lowered from the top without the connection pipes. On each floor you drill one ø130 mm hole through the shaft wall and screw the 500 mm connection pipe onto the branch. With PR C14 Flexible there must be at least 2.5 m of liner between two connections.

How to build your list, from top to bottom

  1. Top: draught cap and shaft cover plate with storm collar (stainless steel), or terminal with spacers (PZ C14 Star).
  2. Pipes up to the highest tee, and between the tees.
  3. One tee per boiler. With PZ C14 Star an absorber goes under each tee.
  4. One connection set per boiler: concentric pipe with finishing plate or rosette.
  5. Bottom: condensate drain and siphon for positive pressure.
  6. Base: starter support plate (stainless steel) or support foot (PZ C14 Star).
  7. For stainless steel: a clamping band on every joint.

For PR C14 Flexible the order is: mounting set at the top, liner, one connection set per boiler, base set and condensate element at the bottom.

Frequently asked questions

What is the difference between C14 and C13?

Both have one common flue. With C14 the air comes through the shaft around the flue, with C13 each appliance has its own air supply.

What diameter does the column need?

It follows from a calculation to EN 13384-2, with the number of boilers, their output, the height and the size of the main duct. Send us the data and we will check it.

Why an absorber under each tee with PZ C14 Star?

Rigid PP expands by about 0.16 mm per metre per degree, over 4 cm on a 3 m floor. The tees are fixed in the wall, so the absorber takes up that length.

Do all boilers have to be replaced at the same time?

Yes. All appliances on the shunt move to the new flue together, because no flue gas may enter the shaft any more.

Filter by:
Stock
  • More Less
Delivery time
  • More Less
Diameter
  • More Less
Colour
  • More Less
Classification
  • More Less
Temperature resistant
  • More Less
Suitable for
  • More Less
Test pressure
  • More Less
Wall thickness
Net weight
  • to
Gasket
  • More Less
Material
  • More Less
Dimensions
  • More Less

C14/C13 shunt renovation: one common flue in the shunt

SROP15.jpg
Start support plate for shunt renovation, stainless steel 316

10 variants

CF5006.jpg
Tube 50 cm concentric CF series

4 variants

IE100-enkelwandige-buis-1-meter-inox
Tube 1 meter single wall stainless IE series

16 variants

trekkende-kap-enkelwandig-inox-rookgasafvoer-ld-flue
Pulling hood single wall stainless IE series

12 variants

klemband-enkelwandig-inox-rookgasafvoer-ld-flue
Clamp single wall stainless IE series

14 variants

condenslekdop-enkelwandig-inox-rookgasafvoer-ld-flue
Condensation leak cap single wall stainless IE series

15 variants

schachtafdekplaat-met-stormkraag-enkelwandig-inox-rookgasafvoer-ld-flue
Shaft cover plate with storm collar single wall stainless IE series

12 variants

t-stuk-90-graden-met-aftakking-80-enkelwandig-inox-rookgasafvoer-ld-flue
T-piece 90° with seal and branch ø80

13 variants

PLW3340100.jpg
Rectangular finishing plate (RAL 9003) with opening

3 variants

PRAMF08110.jpg
Connection set ø80/125 for multiple shunt and CLV

3 variants

PREM110.jpg
Condensation element with drain piece via shaft

3 variants

PRF110.jpg
Black flexible PP per meter

3 variants

PRF110R30.jpg
Black flexible PP per roll (30m)

3 variants

130ppbmf
Basic set for shunt and CLV

3 variants

PRMS110.jpg
Mounting kit 2 (snout end and suspension)

3 variants

buis-1-m-pps-zwart-uv-bestendig-met-mof-rookgasafvoer-ld-flue
Tube 1 meter black PP PZ series

8 variants

afstandhouder-starre-buis-schacht-pps-zwart-ld-flue
Spacer black PP PZ series

6 variants

Absorber 500 mm black PP (expansion joint), PZ C14 Star
Absorber 500 mm black PP (expansion joint), PZ C14 Star

5 variants

Ground support for socket with drain, PZ C14 Star
Ground support for socket with drain, PZ C14 Star

6 variants

C14 tee 87° with screw-on connection pipe (PZC14T)
C14 tee 87° 1 m with screw-on connection pipe, PZ C14 Star

8 variants